Introduction

The P51-750-S-S-P-20MA-000-000 is a crucial component in the field of electronic instrumentation and control systems. This entry will provide an in-depth overview of this product, including its category, use, characteristics, package, essence, packaging/quantity, specifications, detailed pin configuration, functional features, advantages and disadvantages, working principles, detailed application field plans, and alternative models.

Basic Information Overview

  • Category: Electronic Instrumentation Component
  • Use: Measurement and Control Systems
  • Characteristics: High precision, reliability, compact design
  • Package: Sealed unit
  • Essence: Transducer for converting physical parameters into electrical signals
  • Packaging/Quantity: Individual units

Specifications

  • Model: P51-750-S-S-P-20MA-000-000
  • Input Voltage: 5V DC
  • Output Signal: 4-20mA
  • Operating Temperature: -40°C to 85°C
  • Pressure Range: 0-750 psi
  • Material: Stainless Steel
  • Accuracy: ±0.5%

Detailed Pin Configuration

  1. Vcc (Power Supply)
  2. GND (Ground)
  3. Output

Functional Features

  • Accurate pressure sensing
  • Robust construction for harsh environments
  • Low power consumption
  • Linear output signal

Advantages

  • Wide operating temperature range
  • High accuracy
  • Compact size
  • Compatibility with standard control systems

Disadvantages

  • Limited pressure range compared to some alternatives
  • Requires external power supply

Working Principles

The P51-750-S-S-P-20MA-000-000 operates on the principle of strain gauge technology, where the applied pressure causes deformation in the diaphragm, leading to a change in resistance. This change is then converted into a proportional electrical signal.

Detailed Application Field Plans

This transducer is widely used in industrial automation, hydraulic systems, pneumatic systems, and process control applications. It is particularly suitable for pressure measurement in fluid handling systems, HVAC systems, and automotive applications.

Detailed and Complete Alternative Models

  1. P51-1000-S-S-I12-4.5V-000-000
    • Pressure Range: 0-1000 psi
    • Output Signal: 4.5V
    • Material: Stainless Steel
  2. P51-500-S-S-I12-10V-000-000
    • Pressure Range: 0-500 psi
    • Output Signal: 0-10V
    • Material: Stainless Steel
  3. P51-1000-S-S-P-20MA-000-000
    • Pressure Range: 0-1000 psi
    • Output Signal: 4-20mA
    • Material: Stainless Steel

In conclusion, the P51-750-S-S-P-20MA-000-000 plays a vital role in the accurate measurement and control of pressure in various industrial and commercial applications. Its robust design, precise output, and compatibility with standard control systems make it a preferred choice for many engineers and system integrators.

[Word Count: 455]

Lista 10 Vanliga frågor och svar relaterade till tillämpningen av P51-750-S-S-P-20MA-000-000 i tekniska lösningar

  1. What is the P51-750-S-S-P-20MA-000-000 sensor used for?

    • The P51-750-S-S-P-20MA-000-000 sensor is a pressure transducer commonly used to measure and monitor pressure in various technical applications.
  2. What is the pressure range of the P51-750-S-S-P-20MA-000-000 sensor?

    • The pressure range of the P51-750-S-S-P-20MA-000-000 sensor is typically 0-750 psi.
  3. What type of output signal does the P51-750-S-S-P-20MA-000-000 sensor provide?

    • The P51-750-S-S-P-20MA-000-000 sensor provides a 4-20mA output signal, which is commonly used in industrial control systems.
  4. Is the P51-750-S-S-P-20MA-000-000 sensor suitable for use in harsh environments?

    • Yes, the P51-750-S-S-P-20MA-000-000 sensor is designed to withstand harsh environmental conditions and is often used in rugged industrial settings.
  5. What are the typical applications for the P51-750-S-S-P-20MA-000-000 sensor?

    • The P51-750-S-S-P-20MA-000-000 sensor is commonly used in hydraulic systems, industrial machinery, and process control applications.
  6. Does the P51-750-S-S-P-20MA-000-000 sensor require calibration?

    • Yes, the P51-750-S-S-P-20MA-000-000 sensor should be calibrated periodically to ensure accurate pressure measurements.
  7. Can the P51-750-S-S-P-20MA-000-000 sensor be used with corrosive fluids?

    • It depends on the specific model and materials of construction, but some versions of the P51-750-S-S-P-20MA-000-000 sensor are compatible with corrosive fluids.
  8. What is the operating temperature range of the P51-750-S-S-P-20MA-000-000 sensor?

    • The operating temperature range of the P51-750-S-S-P-20MA-000-000 sensor is typically -40°C to 85°C (-40°F to 185°F).
  9. Is the P51-750-S-S-P-20MA-000-000 sensor intrinsically safe?

    • Some versions of the P51-750-S-S-P-20MA-000-000 sensor are available with intrinsically safe certifications for use in hazardous environments.
  10. What is the recommended installation procedure for the P51-750-S-S-P-20MA-000-000 sensor?

    • The P51-750-S-S-P-20MA-000-000 sensor should be installed according to the manufacturer's guidelines, typically involving proper mounting, sealing, and electrical connections.