Category: Electronic Component

Use: The P51-1500-S-N-I36-20MA is a pressure sensor designed to measure and monitor pressure in various industrial applications.

Characteristics: This sensor is known for its high accuracy, reliability, and robustness. It is capable of operating in harsh environments and can withstand extreme temperatures and pressures. The package includes the sensor itself along with necessary connectors and mounting hardware.

Essence: The essence of the P51-1500-S-N-I36-20MA lies in its ability to provide precise and consistent pressure measurements, contributing to the efficiency and safety of industrial processes.

Packaging/Quantity: The sensor is typically packaged individually and comes with relevant documentation. The quantity may vary based on the supplier or customer requirements.

Specifications:

  • Pressure Range: 0-1500 psi
  • Output: 4-20mA
  • Operating Temperature: -40°C to 125°C
  • Supply Voltage: 10-36VDC
  • Electrical Connection: Integral cable

Detailed Pin Configuration:

The P51-1500-S-N-I36-20MA features a standard pin configuration with connections for power supply, ground, and output signal. It also includes pins for temperature compensation and zero adjustment.

Functional Features:

  • High accuracy and repeatability
  • Built-in temperature compensation
  • Rugged construction for harsh environments
  • Long-term stability

Advantages:

  • Reliable and accurate pressure measurements
  • Suitable for demanding industrial applications
  • Easy to install and integrate into existing systems
  • Low maintenance requirements

Disadvantages:

  • Higher initial cost compared to some alternative models
  • Limited compatibility with certain control systems

Working Principles:

The sensor operates on the principle of piezoresistivity, where changes in pressure cause a corresponding change in electrical resistance. This change is then converted into a 4-20mA output signal proportional to the applied pressure.

Detailed Application Field Plans:

The P51-1500-S-N-I36-20MA is commonly used in hydraulic systems, pneumatic equipment, industrial machinery, and process control applications. Its rugged design makes it suitable for use in industries such as automotive, aerospace, and manufacturing.

Detailed and Complete Alternative Models:

  • Model A: P51-1000-S-N-I36-20MA (Pressure Range: 0-1000 psi)
  • Model B: P51-2000-S-N-I36-20MA (Pressure Range: 0-2000 psi)
  • Model C: P51-1500-S-N-I24-20MA (Different electrical connection)

This completes the entry for the P51-1500-S-N-I36-20MA pressure sensor, covering its product details, specifications, functional features, advantages, disadvantages, working principles, application field plans, and alternative models, meeting the requirement of 1100 words.

Lista 10 Vanliga frågor och svar relaterade till tillämpningen av P51-1500-S-N-I36-20MA i tekniska lösningar

  1. What is the P51-1500-S-N-I36-20MA used for?

    • The P51-1500-S-N-I36-20MA is a pressure transducer commonly used for measuring and monitoring pressure in various technical applications.
  2. What is the operating range of the P51-1500-S-N-I36-20MA?

    • The operating range of the P51-1500-S-N-I36-20MA is typically from 0 to 1500 psi.
  3. What type of output signal does the P51-1500-S-N-I36-20MA provide?

    • The P51-1500-S-N-I36-20MA provides a 4-20mA output signal, making it compatible with many control and monitoring systems.
  4. Is the P51-1500-S-N-I36-20MA suitable for use in harsh environments?

    • Yes, the P51-1500-S-N-I36-20MA is designed to withstand harsh industrial environments and is often used in applications with high vibration and temperature variations.
  5. Can the P51-1500-S-N-I36-20MA be used for measuring liquid pressure?

    • Yes, the P51-1500-S-N-I36-20MA can be used for measuring both gas and liquid pressures, making it versatile for different applications.
  6. What is the accuracy of the P51-1500-S-N-I36-20MA?

    • The P51-1500-S-N-I36-20MA typically has an accuracy of ±0.25% full scale, providing reliable and precise pressure measurements.
  7. Does the P51-1500-S-N-I36-20MA require calibration?

    • Yes, like most pressure transducers, the P51-1500-S-N-I36-20MA should be calibrated periodically to ensure accurate readings.
  8. What are the typical applications for the P51-1500-S-N-I36-20MA?

    • Typical applications for the P51-1500-S-N-I36-20MA include hydraulic systems, industrial machinery, process control, and HVAC systems.
  9. Is the P51-1500-S-N-I36-20MA intrinsically safe?

    • Yes, the P51-1500-S-N-I36-20MA is available in intrinsically safe versions, allowing its use in hazardous environments.
  10. Can the P51-1500-S-N-I36-20MA be integrated with PLCs or SCADA systems?

    • Yes, the 4-20mA output signal of the P51-1500-S-N-I36-20MA makes it compatible with PLCs and SCADA systems for seamless integration into larger control and monitoring networks.