Bild kan vara representation.
Se specifikationer för produktinformation.
P51-1000-S-L-M12-20MA-000-000

P51-1000-S-L-M12-20MA-000-000

Product Overview

Category

The P51-1000-S-L-M12-20MA-000-000 belongs to the category of industrial pressure sensors.

Use

It is used for measuring and monitoring pressure in various industrial applications.

Characteristics

  • High accuracy
  • Robust construction
  • Wide operating temperature range
  • Compatibility with different media
  • Long-term stability

Package

The sensor is typically packaged in a protective housing to ensure durability and reliability during transportation and installation.

Essence

The essence of the P51-1000-S-L-M12-20MA-000-000 lies in its ability to provide precise and reliable pressure measurements in challenging industrial environments.

Packaging/Quantity

The sensor is usually packaged individually and is available in varying quantities based on customer requirements.

Specifications

  • Pressure Range: 0-1000 psi
  • Output: 4-20 mA
  • Electrical Connection: M12 connector
  • Operating Temperature: -40°C to 125°C
  • Pressure Type: Sealed gauge
  • Material: Stainless steel

Detailed Pin Configuration

The detailed pin configuration of the P51-1000-S-L-M12-20MA-000-000 includes: - Pin 1: Power supply - Pin 2: Signal output - Pin 3: Ground

Functional Features

  • High precision pressure measurement
  • Compatibility with various industrial fluids
  • Compact and rugged design
  • Easy integration into existing systems
  • Long-term stability and reliability

Advantages

  • Accurate and reliable pressure measurements
  • Suitable for harsh industrial environments
  • Easy to install and integrate
  • Long-term stability and durability
  • Wide operating temperature range

Disadvantages

  • Limited pressure range compared to some other industrial sensors
  • Requires compatible M12 connector for electrical connection

Working Principles

The P51-1000-S-L-M12-20MA-000-000 operates on the principle of strain gauge technology, where changes in pressure cause deformation in the sensor's diaphragm, leading to a change in resistance and subsequently the output signal.

Detailed Application Field Plans

The P51-1000-S-L-M12-20MA-000-000 is suitable for a wide range of industrial applications, including: - Hydraulic systems - Process control - Industrial machinery - Automotive testing - Aerospace applications

Detailed and Complete Alternative Models

Some alternative models to the P51-1000-S-L-M12-20MA-000-000 include: - P51-500-S-N-I12-5V-000-000 - P51-2000-S-L-M12-10V-000-000 - P51-250-S-L-M12-4-20MA-000-000

In conclusion, the P51-1000-S-L-M12-20MA-000-000 offers high-precision pressure measurement capabilities, making it an ideal choice for various industrial applications. Its robust construction, wide operating temperature range, and compatibility with different media make it a versatile solution for pressure monitoring needs. While it has certain limitations, such as a limited pressure range, its advantages outweigh the disadvantages, making it a valuable asset in industrial settings.

Lista 10 Vanliga frågor och svar relaterade till tillämpningen av P51-1000-S-L-M12-20MA-000-000 i tekniska lösningar

  1. What is the P51-1000-S-L-M12-20MA-000-000 used for?

    • The P51-1000-S-L-M12-20MA-000-000 is a pressure transducer commonly used for measuring and monitoring pressure in various technical applications.
  2. What is the operating range of the P51-1000-S-L-M12-20MA-000-000?

    • The operating range of the P51-1000-S-L-M12-20MA-000-000 is typically from 0 to 1000 psi, making it suitable for a wide range of pressure measurement needs.
  3. What type of output signal does the P51-1000-S-L-M12-20MA-000-000 provide?

    • The P51-1000-S-L-M12-20MA-000-000 provides a 4-20mA output signal, which is commonly used for transmitting pressure data to control systems or data acquisition devices.
  4. Is the P51-1000-S-L-M12-20MA-000-000 suitable for use in harsh environments?

    • Yes, the P51-1000-S-L-M12-20MA-000-000 is designed to withstand harsh industrial environments and is often used in applications where exposure to extreme conditions is expected.
  5. What are the typical applications for the P51-1000-S-L-M12-20MA-000-000?

    • The P51-1000-S-L-M12-20MA-000-000 is commonly used in hydraulic systems, industrial machinery, process control, and HVAC systems for pressure monitoring and control.
  6. Does the P51-1000-S-L-M12-20MA-000-000 require calibration?

    • Yes, like most pressure transducers, the P51-1000-S-L-M12-20MA-000-000 requires periodic calibration to ensure accurate and reliable measurements.
  7. Can the P51-1000-S-L-M12-20MA-000-000 be integrated with PLCs or SCADA systems?

    • Yes, the 4-20mA output signal of the P51-1000-S-L-M12-20MA-000-000 makes it compatible with most PLCs and SCADA systems for seamless integration into larger control and monitoring systems.
  8. What is the accuracy of the P51-1000-S-L-M12-20MA-000-000?

    • The P51-1000-S-L-M12-20MA-000-000 typically offers high accuracy, often within ±0.25% of full scale, ensuring precise pressure measurements.
  9. Is the P51-1000-S-L-M12-20MA-000-000 suitable for use with corrosive media?

    • Depending on the specific model and materials of construction, the P51-1000-S-L-M12-20MA-000-000 can be configured to handle corrosive media, making it versatile for various applications.
  10. What are the installation requirements for the P51-1000-S-L-M12-20MA-000-000?

    • The P51-1000-S-L-M12-20MA-000-000 typically requires proper mounting and sealing to ensure accurate pressure readings, and it's important to follow the manufacturer's guidelines for installation.