Bild kan vara representation.
Se specifikationer för produktinformation.
P51-100-S-D-MD-20MA-000-000

P51-100-S-D-MD-20MA-000-000

Product Overview

Category

The P51-100-S-D-MD-20MA-000-000 belongs to the category of precision pressure transducers.

Use

It is used for accurately measuring and transmitting pressure readings in various industrial and commercial applications.

Characteristics

  • High precision
  • Reliable performance
  • Compact design
  • Wide operating temperature range
  • Long-term stability

Package

The product is typically packaged in a protective casing to ensure safe transportation and storage.

Essence

The essence of the P51-100-S-D-MD-20MA-000-000 lies in its ability to provide accurate and consistent pressure measurements in diverse environments.

Packaging/Quantity

The standard packaging includes individual units, and the quantity may vary based on customer requirements.

Specifications

  • Model: P51-100-S-D-MD-20MA-000-000
  • Pressure Range: 0-100 psi
  • Output: 4-20 mA
  • Operating Temperature: -40°C to 85°C
  • Accuracy: ±0.5% full scale
  • Electrical Connection: Dual pins

Detailed Pin Configuration

The detailed pin configuration of the P51-100-S-D-MD-20MA-000-000 is as follows: 1. Vcc 2. Ground 3. Signal + 4. Signal -

Functional Features

  • Linear output proportional to pressure
  • Built-in temperature compensation
  • Overpressure protection
  • Easy installation and integration

Advantages

  • High accuracy and reliability
  • Suitable for harsh environments
  • Low power consumption
  • Long-term stability

Disadvantages

  • May require additional signal conditioning in some applications
  • Initial cost may be higher compared to standard pressure sensors

Working Principles

The P51-100-S-D-MD-20MA-000-000 operates on the principle of converting applied pressure into an electrical signal using a sensitive diaphragm and strain gauge technology. The resulting signal is then linearized and transmitted as a 4-20 mA output.

Detailed Application Field Plans

The P51-100-S-D-MD-20MA-000-000 is widely used in: - Industrial automation - Hydraulic systems - Process control - HVAC systems - Aerospace and automotive industries

Detailed and Complete Alternative Models

  • P51-50-S-B-MD-20MA-000-000
  • P51-200-S-D-MD-20MA-000-000
  • P51-100-S-D-MD-10MA-000-000

This concludes the English editing encyclopedia entry structure for the P51-100-S-D-MD-20MA-000-000, providing comprehensive information about its product details, specifications, features, and applications.

Lista 10 Vanliga frågor och svar relaterade till tillämpningen av P51-100-S-D-MD-20MA-000-000 i tekniska lösningar

  1. What is the P51-100-S-D-MD-20MA-000-000?

    • The P51-100-S-D-MD-20MA-000-000 is a pressure sensor designed for industrial applications, capable of measuring pressure and providing a 4-20mA output signal.
  2. What is the operating range of the P51-100-S-D-MD-20MA-000-000?

    • The operating range of the P51-100-S-D-MD-20MA-000-000 is typically from 0 to 100 psi, making it suitable for a wide range of pressure measurement tasks.
  3. What are the key features of the P51-100-S-D-MD-20MA-000-000?

    • The key features of the P51-100-S-D-MD-20MA-000-000 include its rugged design, high accuracy, 4-20mA output, and compatibility with various media types.
  4. How is the P51-100-S-D-MD-20MA-000-000 installed?

    • The P51-100-S-D-MD-20MA-000-000 can be installed using standard mounting techniques, such as NPT fittings or flanges, depending on the specific application requirements.
  5. What are the typical applications for the P51-100-S-D-MD-20MA-000-000?

    • The P51-100-S-D-MD-20MA-000-000 is commonly used in industrial automation, hydraulic systems, pneumatic systems, and process control applications.
  6. Is the P51-100-S-D-MD-20MA-000-000 compatible with corrosive media?

    • Yes, the P51-100-S-D-MD-20MA-000-000 is available with various diaphragm materials to ensure compatibility with a wide range of media, including corrosive substances.
  7. What is the temperature range for the P51-100-S-D-MD-20MA-000-000?

    • The P51-100-S-D-MD-20MA-000-000 is designed to operate within a temperature range of -40°C to 85°C, allowing for reliable performance in diverse environments.
  8. Can the P51-100-S-D-MD-20MA-000-000 be integrated with PLC systems?

    • Yes, the 4-20mA output signal of the P51-100-S-D-MD-20MA-000-000 makes it compatible with most PLC systems, enabling seamless integration into industrial control networks.
  9. What maintenance is required for the P51-100-S-D-MD-20MA-000-000?

    • The P51-100-S-D-MD-20MA-000-000 generally requires minimal maintenance, with periodic calibration checks and inspection of the diaphragm and seals being recommended.
  10. Is the P51-100-S-D-MD-20MA-000-000 suitable for hazardous environments?

    • Yes, the P51-100-S-D-MD-20MA-000-000 is available with intrinsically safe and explosion-proof certifications, making it suitable for use in hazardous environments where flammable gases or vapors may be present.