Introduction

The KSD261GTA is a crucial component in the field of electronic devices, offering a wide range of applications and functionalities. This entry provides an in-depth analysis of the product, covering its basic information, specifications, pin configuration, functional features, advantages and disadvantages, working principles, application field plans, and alternative models.

Basic Information Overview

  • Category: Electronic Component
  • Use: Temperature Control Switch
  • Characteristics: High precision, reliable performance, compact design
  • Package: TO-220, TO-220F, TO-263
  • Essence: Regulates temperature within electronic devices
  • Packaging/Quantity: Typically packaged in reels or tubes, quantity varies based on manufacturer

Specifications

  • Operating Temperature Range: -10°C to 250°C
  • Contact Rating: 10A/250VAC
  • Insulation Resistance: ≥100MΩ
  • Dielectric Strength: 1500VAC for 1 minute
  • Electrical Life: ≥10,000 cycles

Detailed Pin Configuration

The KSD261GTA typically features a standard pin configuration with three pins: 1. Pin 1: Normally Open (NO) 2. Pin 2: Common (COM) 3. Pin 3: Normally Closed (NC)

Functional Features

  • Temperature Sensing: Precisely detects temperature changes
  • Switching Action: Automatically opens or closes electrical circuits based on temperature thresholds
  • Reliability: Ensures stable and consistent performance over extended usage

Advantages and Disadvantages

Advantages

  • High Precision: Offers accurate temperature control
  • Reliable Performance: Ensures consistent operation in diverse conditions
  • Compact Design: Facilitates integration into various electronic devices

Disadvantages

  • Limited Temperature Range: May not be suitable for extreme temperature environments
  • Mechanical Wear: Prone to wear and tear over prolonged use

Working Principles

The KSD261GTA operates based on the principle of bimetallic strip expansion and contraction. When the temperature reaches the set threshold, the bimetallic strip triggers a mechanical action, either opening or closing the electrical circuit, thereby regulating the temperature within the device.

Detailed Application Field Plans

The KSD261GTA finds extensive application in various industries, including: - Home Appliances: Used in refrigerators, water heaters, and air conditioners for temperature regulation - Industrial Equipment: Integrated into machinery and equipment to prevent overheating - Automotive Sector: Employed in automotive cooling systems for thermal management

Detailed and Complete Alternative Models

Several alternative models offer similar functionality to the KSD261GTA, including: - KSD301GTA - KSD302GTA - KSD303GTA - KSD305GTA

In conclusion, the KSD261GTA serves as a vital component in temperature control systems, providing precise and reliable performance across diverse applications.

[Word Count: 411]

Lista 10 Vanliga frågor och svar relaterade till tillämpningen av KSD261GTA i tekniska lösningar

  1. What is KSD261GTA?

    • KSD261GTA is a type of thermal switch commonly used in technical solutions to control temperature by opening or closing electrical circuits.
  2. How does KSD261GTA work?

    • KSD261GTA operates based on the principle of bimetallic strip movement, which causes the switch to open or close at a specific temperature, thus controlling the electrical circuit.
  3. What is the temperature range of KSD261GTA?

    • The temperature range of KSD261GTA typically varies from 0°C to 150°C, making it suitable for various applications requiring temperature control.
  4. What are the common applications of KSD261GTA?

    • KSD261GTA is commonly used in appliances such as electric kettles, coffee makers, water heaters, and other devices that require temperature regulation.
  5. How do I install KSD261GTA in my technical solution?

    • To install KSD261GTA, you need to carefully follow the manufacturer's instructions, ensuring proper wiring and placement to achieve accurate temperature control.
  6. Can KSD261GTA be used for both heating and cooling applications?

    • No, KSD261GTA is specifically designed for heating applications and is not suitable for cooling purposes.
  7. Is KSD261GTA suitable for high-current applications?

    • KSD261GTA is typically designed for low to moderate current applications and may not be suitable for high-current scenarios without additional measures.
  8. What are the key considerations when selecting KSD261GTA for a technical solution?

    • When selecting KSD261GTA, factors such as the operating temperature range, current rating, physical dimensions, and environmental conditions should be carefully considered.
  9. Can KSD261GTA be reset after tripping at a certain temperature?

    • KSD261GTA can often be manually reset after tripping, allowing for continued operation once the temperature returns to the normal range.
  10. Are there any safety precautions to consider when using KSD261GTA?

    • It is important to ensure that KSD261GTA is used within its specified parameters to avoid overheating, electrical hazards, or damage to the device or the technical solution. Regular maintenance and inspection are also recommended to ensure safe and reliable operation.