Bild kan vara representation.
Se specifikationer för produktinformation.
MAX6316LUK29BX-T

MAX6316LUK29BX-T

Product Overview

  • Category: Integrated Circuit (IC)
  • Use: Voltage Monitor
  • Characteristics: Low-power, precision voltage monitoring
  • Package: SOT23-5
  • Essence: Monitors the voltage level of a power supply and provides an output signal when it falls below a certain threshold.
  • Packaging/Quantity: Tape and Reel, 3000 units per reel

Specifications

  • Supply Voltage Range: 1.6V to 5.5V
  • Threshold Voltage Options: 2.9V
  • Operating Temperature Range: -40°C to +85°C
  • Quiescent Current: 3µA (typical)

Detailed Pin Configuration

The MAX6316LUK29BX-T has a total of five pins:

  1. GND: Ground connection
  2. VCC: Positive supply voltage input
  3. RESET#: Active-low reset output
  4. MR#: Manual reset input
  5. TH: Threshold voltage selection pin

Functional Features

  • Voltage Monitoring: The MAX6316LUK29BX-T continuously monitors the supply voltage and asserts the RESET# output when it drops below the threshold voltage.
  • Manual Reset: The MR# input allows for manual resetting of the device, overriding the voltage monitoring function.
  • Precision: The IC provides accurate voltage monitoring with a low threshold voltage option of 2.9V.
  • Low Power Consumption: With a quiescent current of only 3µA, the MAX6316LUK29BX-T is designed for low-power applications.

Advantages and Disadvantages

Advantages: - Precise voltage monitoring - Low power consumption - Manual reset capability - Small package size

Disadvantages: - Limited threshold voltage options - Single threshold voltage setting

Working Principles

The MAX6316LUK29BX-T operates by comparing the supply voltage with the threshold voltage set by the TH pin. When the supply voltage drops below the threshold, the RESET# output is asserted, indicating a power failure or an out-of-tolerance condition. The MR# input allows for manual resetting of the device, overriding the voltage monitoring function.

Detailed Application Field Plans

The MAX6316LUK29BX-T is commonly used in various applications where reliable voltage monitoring is critical. Some potential application fields include:

  1. Battery-Powered Devices: Ensuring proper operation and preventing damage due to low battery voltage.
  2. Industrial Control Systems: Monitoring power supply integrity to prevent equipment malfunction or data loss.
  3. Automotive Electronics: Protecting sensitive components from voltage fluctuations and ensuring safe operation.
  4. Medical Equipment: Ensuring continuous power supply for critical medical devices.

Detailed and Complete Alternative Models

  1. MAX6316LUK29BY-T: Same functionality as MAX6316LUK29BX-T but with a different threshold voltage option (2.9V).
  2. MAX6316LUK30BX-T: Similar features as MAX6316LUK29BX-T but with a higher threshold voltage option (3.0V).
  3. MAX6316LUK28BX-T: Similar features as MAX6316LUK29BX-T but with a lower threshold voltage option (2.8V).

(Note: This list is not exhaustive and there may be other alternative models available.)

Word count: 346 words

Lista 10 Vanliga frågor och svar relaterade till tillämpningen av MAX6316LUK29BX-T i tekniska lösningar

Sure! Here are 10 common questions and answers related to the application of MAX6316LUK29BX-T in technical solutions:

1. What is MAX6316LUK29BX-T? - MAX6316LUK29BX-T is a voltage monitor and reset circuit IC manufactured by Maxim Integrated. It is used to monitor the power supply voltage and generate a reset signal when the voltage falls below a certain threshold.

2. What is the operating voltage range of MAX6316LUK29BX-T? - The operating voltage range of MAX6316LUK29BX-T is from 1.8V to 5.5V.

3. How does MAX6316LUK29BX-T help in technical solutions? - MAX6316LUK29BX-T ensures proper system operation by monitoring the power supply voltage and generating a reset signal to initiate a controlled system restart or shutdown when the voltage drops below a specified level.

4. What is the typical reset threshold voltage of MAX6316LUK29BX-T? - The typical reset threshold voltage of MAX6316LUK29BX-T is 2.93V.

5. Can I adjust the reset threshold voltage of MAX6316LUK29BX-T? - No, the reset threshold voltage of MAX6316LUK29BX-T is fixed and cannot be adjusted.

6. Does MAX6316LUK29BX-T have an open-drain output? - Yes, MAX6316LUK29BX-T has an open-drain RESET output.

7. What is the maximum sink current capability of the RESET output? - The maximum sink current capability of the RESET output is 20mA.

8. Is MAX6316LUK29BX-T suitable for battery-powered applications? - Yes, MAX6316LUK29BX-T is suitable for battery-powered applications as it operates within a wide voltage range and has low quiescent current consumption.

9. Can MAX6316LUK29BX-T be used in automotive applications? - Yes, MAX6316LUK29BX-T is automotive-grade and can be used in automotive applications.

10. Does MAX6316LUK29BX-T have any additional features? - Yes, MAX6316LUK29BX-T includes a manual reset input, which allows an external signal to force a system reset regardless of the monitored voltage level.

Please note that these answers are based on general information about MAX6316LUK29BX-T. For specific details and application requirements, it is recommended to refer to the datasheet or consult with Maxim Integrated's technical support.