The MAX16058ATA26+T has a total of six pins arranged as follows:
```
| | --| VCC GND |-- Pin 1: Ground (GND) --| RESET OUT |-- Pin 2: Reset Output (RESET OUT) --| THRESHOLD |-- Pin 3: Threshold Voltage Input (THRESHOLD) --| MR/ |-- Pin 4: Manual Reset Input / Active-Low Reset Input (MR/) --| RESET |-- Pin 5: Power-On Reset Input (RESET) --| IN |-- Pin 6: Supply Voltage Input (IN) |___________| ```
The MAX16058ATA26+T operates by continuously monitoring the supply voltage through the THRESHOLD pin. When the voltage drops below the user-defined threshold, the RESET OUT pin is asserted low, indicating a reset condition. The reset signal remains active until the supply voltage rises above the threshold and the reset timeout period elapses.
The MAX16058ATA26+T finds applications in various electronic systems where reliable voltage monitoring and reset functionality are required. Some potential application fields include:
These alternative models offer similar functionality with slight variations to cater to different application requirements.
Word count: 442 words
Sure! Here are 10 common questions and answers related to the application of MAX16058ATA26+T in technical solutions:
Q: What is the MAX16058ATA26+T? A: The MAX16058ATA26+T is a low-power, voltage-monitoring circuit designed for use in various technical solutions.
Q: What is the purpose of the MAX16058ATA26+T? A: The MAX16058ATA26+T is used to monitor the voltage levels in a system and provide alerts or trigger actions based on predefined thresholds.
Q: How does the MAX16058ATA26+T work? A: The MAX16058ATA26+T continuously monitors the voltage levels using an internal voltage reference and compares them to user-defined thresholds. It generates an output signal when the voltage exceeds or falls below these thresholds.
Q: What is the operating voltage range of the MAX16058ATA26+T? A: The MAX16058ATA26+T operates within a voltage range of 1.6V to 5.5V.
Q: Can the MAX16058ATA26+T be used in battery-powered applications? A: Yes, the low-power design of the MAX16058ATA26+T makes it suitable for battery-powered applications.
Q: What is the output configuration of the MAX16058ATA26+T? A: The MAX16058ATA26+T provides an open-drain output that can be pulled up to a supply voltage using an external resistor.
Q: Can the MAX16058ATA26+T be used to monitor multiple voltage levels simultaneously? A: Yes, the MAX16058ATA26+T has multiple voltage monitoring inputs, allowing it to monitor multiple voltage levels in a system.
Q: What is the typical accuracy of the voltage monitoring thresholds? A: The typical accuracy of the voltage monitoring thresholds in the MAX16058ATA26+T is ±1.5%.
Q: Can the MAX16058ATA26+T be used in industrial applications? A: Yes, the MAX16058ATA26+T is suitable for use in various industrial applications due to its wide operating temperature range and robust design.
Q: Are there any additional features or functionalities of the MAX16058ATA26+T? A: Yes, the MAX16058ATA26+T includes a manual reset input, hysteresis control, and a power-on reset delay to enhance its functionality in technical solutions.
Please note that these questions and answers are general and may vary depending on specific application requirements.